Water Foam Monitors
Water foam monitors have a wide range of applications in various industries and emergency response scenarios. These versatile devices are designed to deliver water mixed with foam concentrate to control and extinguish fires effectively.
Let's explore some of the key applications of water foam monitors:
1. Industrial Fire Protection: Water foam monitors are extensively used in industrial settings such as refineries, chemical plants, warehouses, and manufacturing facilities. They provide an efficient way to suppress and extinguish fires involving flammable liquids, gases, and combustible materials.
2. Petrochemical Industry: In the petrochemical industry, where the risk of fires is high, water foam monitors are essential safety tools. They can swiftly deliver a foam blanket to smother flammable liquid fires, preventing their spread and minimizing the risk of explosions.
3. Aircraft Hangars: The large open spaces in aircraft hangars make them susceptible to rapid fire spread. Water foam monitors are strategically placed to cover a wide area and provide rapid fire suppression capabilities in case of an aircraft or fuel-related fire.
4. Oil and Gas Facilities: Offshore platforms, oil drilling rigs, and onshore oil and gas processing facilities face inherent fire hazards. Water foam monitors play a crucial role in suppressing fires in these environments, providing effective firefighting capabilities to protect personnel, equipment, and infrastructure.
5. Storage Tank Farms: Foam monitors are commonly used in storage tank farms, where flammable liquids are stored in large tanks. They can deliver foam over a long distance, covering the surface of the liquid and creating a vapor-sealing blanket that suppresses fires and prevents reignition.
6. Firefighting Vehicles: Water foam monitors are often mounted on fire trucks and firefighting vehicles. These monitors enable firefighters to deliver a powerful stream of foam from a safe distance, enhancing their ability to control fires efficiently and protect lives and property.
7. Wildfire Control: Water foam monitors are instrumental in combating wildfires. They can be strategically placed to create firebreaks by covering vegetation or structures with foam, preventing the fire from spreading further.
In summary, water foam monitors find widespread application in industrial fire protection, petrochemical facilities, aircraft hangars, oil and gas sites, storage tank farms, firefighting vehicles, and wildfire control. Their versatility and effectiveness make them indispensable tools in ensuring safety and mitigating the devastating impact of fires.
WATER FOAM MONITORS
1.
GEARED
SWIVELED WATER MONITOR / HIGH VOLUME LONG RANGE MONITORS
|
General Data |
|
|
Model |
Stand Post
Type, Geared Swivel |
|
Inlet |
Flanged 100 -
150 NB IS:1538 / ANSI B 16.5 150# |
|
Outlet |
Threaded
Mounting attached Nozzle |
|
Material of Construction |
|||
|
Parts |
Carbon Steel |
Stainless Steel
304 |
Stainless Steel
316 |
|
Base Flange |
IS 2062 / A 105 |
SS 304 |
SS 316 |
|
Water Barrel |
IS 1239 Part I
Seamless A106 Gr. B |
SS 304 |
SS 316 |
|
Swivel Joint |
Gun Metal IS
318 LTB II |
SS 304 |
SS 316 |
|
Bends |
Carbon Steel IS
4310 |
SS 304 |
SS 316 |
|
Handwheel |
SS 304 |
SS 304 |
SS 304 |
|
Nozzle |
Aluminum IS 617
/ Gun Metal IS 318 LTB – 2 / SS 304 / 316 / IS 3444 Gr. I / IV |
||
|
Testing and Quality Control |
||||||
|
Model |
Operating
Pressure |
Flow Range
(LPM) |
Barrel Size |
Inlet Flange |
Flow (LPM) |
Range (Meters) |
|
KFP 500 |
6 – 12 Kg / Cm2
(g) |
1800 - 2000 |
63 |
100 |
1850 |
54 |
|
KFP 675 |
2400 - 2700 |
75 |
100 |
2550 |
60 |
|
|
KFP 750 |
7 – 12 Kg / Cm2
(g) |
2700 - 3000 |
80 |
100 |
2850 |
62 |
|
KFP 1000 |
3600 - 4000 |
100 |
100 |
3785 |
72 |
|
|
KFP 2000 |
7000 - 8000 |
150 |
150 |
7570 |
85 |
|
|
Operational & Technical Data |
|
|
Working
Pressure (For Foam Equp.) |
5 to 14 Kgf/cm2 |
|
Manouverability |
+900 /
-450 in vertical plane and 3600 in horizontal Plane |
|
Finish |
Painted with
Red Color (As per Customer Requirements |
2.
Super
Jet Water Monitors
|
General Data |
|
|
Model |
Stand Post
Type, Manual Swivel |
|
Inlet |
Flanged 75 –
100 – 150 NB IS:1538 / ANSI B 16.5 150# |
|
Outlet |
Threaded
Mounting attached Super Jet Nozzle |
|
Material of Construction |
|||
|
Parts |
Carbon Steel |
Stainless Steel
304 |
Stainless Steel
316 |
|
Base Flange |
IS 2062 / A 105 |
SS 304 |
SS 316 |
|
Water Barrel |
IS 1239 Part I
Seamless A106 Gr. B |
SS 304 |
SS 316 |
|
Swivel Joint |
Bronze |
SS 304 |
SS 316 |
|
Bends |
Carbon Steel IS
4310 |
SS 304 |
SS 316 |
|
Handwheel |
SS 304 |
SS 304 |
SS 304 |
|
Nozzle |
Aluminum IS 617
/ Gun Metal IS 318 LTB – 2 / SS 304 / 316 / IS 3444 Gr. I / IV |
||
|
Testing and Quality Control |
|
|||||
|
Model |
Operating
Pressure |
Flow Range
(LPM) |
Barrel Size |
Inlet Flange |
Flow (LPM) |
Range (Meters) |
|
KFP 1750 |
6 – 12 Kg / Cm2
(g) |
1500 - 2500 |
63 |
75 / 100 |
1750 |
55 |
|
KFP 2580 |
1800 - 3500 |
75 |
100 |
2580 |
60 |
|
|
KFP 3750 |
7 – 12 Kg / Cm2
(g) |
2500 - 5500 |
100 |
100 / 150 |
3750 |
65 |
|
Operational & Technical Data |
|
|
Working
Pressure (For Foam Equp.) |
5 to 10 Kgf/cm2 |
|
Manouverability |
+900 /
-450 in vertical plane and 3600 in horizontal Plane |
|
Finish |
Painted with
Red Color (As per Customer Requirements |
3.
Oscillating
water Monitors
|
General Data |
||
|
Model |
Oscillating
Monitors |
|
|
Inlet |
Flanged 100 NB
IS:1538 / ANSI B 16.5 150# |
|
|
Outlet |
Threaded
Mounting 3” attached Stream Nozzle |
|
|
Oscillating
Angle |
300 500
700 1000 |
|
|
Nozzle Type |
Jet / Spray /
Fog Type |
|
|
Material of Construction |
|||
|
Parts |
Carbon Steel |
Stainless Steel
304 |
Stainless Steel
316 |
|
Base Flange |
IS 2062 / A 105 |
SS 304 |
SS 316 |
|
Water Barrel |
IS 1239 Part I
Seamless A106 Gr. B |
SS 304 |
SS 316 |
|
Swivel Joint |
Bronze |
SS 304 |
SS 316 |
|
Bends |
Carbon Steel IS
4310 |
SS 304 |
SS 316 |
|
Handwheel |
SS 304 |
SS 304 |
SS 304 |
|
Nozzle |
SS 304 |
||
|
Testing and Quality Control |
|||||||
|
Model |
Operating
Pressure |
Flow Range
(LPM) |
Barrel Size |
Inlet Flange |
Flow (LPM) |
Range (Meters)
Water |
Range (Meters) Foam |
|
KFPO |
5 – 12 Kg / Cm2
(g) |
1800 - 3800 |
75 |
100 |
3800 |
65 |
55 |
|
Operational & Technical Data |
|
|
Working
Pressure (For Foam Equp.) |
5 to 12 Kgf/cm2 |
|
Finish |
Painted with
Red Color (As per Customer Requirements |
4.
Portable Water Monitor:
|
General Data |
||
|
Model |
Portable
Monitors |
|
|
Inlet |
2 Nos. 63mm
Inst. Male Inlets |
|
|
Outlet |
Threaded Mounting
3” attached Stream Nozzle |
|
|
Nozzle Type |
Jet / Spray /
Fog Type |
|
|
Material of Construction |
|||
|
Parts |
Aluminum |
Stainless Steel
304 |
Stainless Steel
316 |
|
Body |
Aluminum |
SS 304 |
SS 316 |
|
Swivel Joint |
Gun Metal |
Gun Metal |
Gun Metal |
|
Worm Shaft |
SS 304 |
SS 304 |
SS 316 |
|
Support Leg |
SS 304 |
SS 304 |
SS 304 |
|
Nozzle |
Aluminum |
Aluminum |
Aluminum |
|
Male Inlets |
Gun Metal |
SS 304 |
SS 316 |
|
Testing and Quality Control |
|||||||
|
Model |
Operating
Pressure |
Flow Range
(LPM) |
Barrel Size |
Inlet |
Flow (LPM) |
Range (Meters)
Water |
Range (Meters) Foam |
|
KFPO |
5 – 10 Kg / Cm2
(g) |
2300 |
75 |
63 mm |
2300 |
60 |
55 |
|
Operational & Technical Data |
|
|
Working
Pressure (For Foam Equp.) |
5 to 10 Kgf/cm2 |
|
Finish |
Painted with
Red Color (As per Customer Requirements |

Comments
Post a Comment
For any further doubt / clarifications please do visit our website www.firefightingequipment.co.in or email us at info@kindefire.co.in or whatsapp us at +91-8141899444